Machine Digital Readouts

Suppliers of Digital Readouts for Engineering Machinery...

 

GS200 Dimensions & Reading Lengths

GS200 Dimensions

When working out the required length of scale, simply measure the table/bed travel in mm, and using the L0 (reading length) dimension below select a scale which has a longer reading length than table travel. If the table/bed travel is greater than the reading length, damage may occur to the scale. To prevent this a fixed mechanical stop should be fitted.

L0
- Reading length. L1 - Distance between mounting hole. L2 - Overall length


Model
Number
L0 L1 L2
mm inch mm inch mm inch
GS200-70 70 2 3/4 165 6 1/2 173 6 13/16
GS200-120 120 4 3/4 215 8 15/32 223 8 6/8
GS200-170 170 6 3/4 265 10 7/16 273 10 3/4
GS200-220 220 8 5/8 315 12 7/16 323 12 11/16
GS200-280 280 11 375 14 1/2 383 15 1/8
GS200-320 320 12 9/16 415 16 3/8 423 16 11/16

  
 
GS200 Technical Information & Specifications

Glass Linear Scales - Specification

Resolution 5µm
Accuracy ± 10µm (at 20 °C / 68 °F)
Max Reading Speed 60m/min
Working Temperature 0~45°C
Cross Section Size (mm) 16x16
Output 5v TTL 90 degree phase difference
Pitch (lines per mm) 0.02mm (50 lines/mm)
Repeatability ±1 counting impulse
Cable length 2 meter armored
Protection IP53 when installed as per intructions

 
Images & Content © Allendale Electronics Limited.
E&OE - Specifications subject to change without prior notice.